Flow Cytometry with Plant Cells. Analysis of Genes, by Christopher A. Cullis.

Posted by

By Christopher A. Cullis.

Certain at newbies in addition to skilled clients, this useful reference explains the advantages and makes use of of circulation cytometery within the learn of vegetation and their genomes. Following a quick creation that highlights common issues whilst studying plant cells via circulate cytometric tools, the ebook is going directly to speak about examples of program in plant genetics, genomic research, mobilephone cycle research, marine organism research and breeding studies.With its record of common studying and a word list of phrases, this primary reference on FCM in vegetation fills a true hole via offering first-hand useful tricks for the turning out to be group of plant geneticists.

Show description

Read or Download Flow Cytometry with Plant Cells. Analysis of Genes, Chromosomes and Genomes, 2007, p.480 PDF

Best plants: botany books

Plant Hormones: Methods and Protocols

The final ten years have witnessed a huge raise in our figuring out of plant hormones. A decade in the past, scientists have been pressured to depend upon obscure principles approximately hormone motion; at the present time, those were changed by way of distinctive molecular versions. Given the quick bring up in our realizing of plant hormone biology, this entire overview couldn't have come at a greater time.

Botanical Medicine: From Bench to Bedside

Botanical drugs: From Bench to Bedside ЗДОРОВЬЕ,НАУКА и УЧЕБА Название: Botanical drugs: From Bench to BedsideАвтор: Raymond Cooper Издательство: Mary Ann Liebert, Inc Год: 2009-06-23 Страниц: 237ISBN: 1934854050 Формат: pdf Размер: 3,5 MB Язык: АнглийскийСправочник по ботанической медицине. Скачать .

Extra info for Flow Cytometry with Plant Cells. Analysis of Genes, Chromosomes and Genomes, 2007, p.480

Sample text

Subsequent versions of this instrument, which incorporated a dedicated computer system, could measure as many as four cellular parameters (Kamentsky and Melamed 1969). A brief trial on cervical cytology specimens indicated that the system had some ability to discriminate normal from abnormal cells (Koenig et al. 1968); it could also produce distinguishable signals from different types of cells in blood samples stained with a combination of acidic and basic dyes. The first commercial flow cytometric differential leukocyte counter, introduced in the early 1970s, was the Hemalog D (Technicon Corporation, now Bayer, Tarrytown, NY, USA); Ornstein was a prime mover in its development, having interacted with Kamentsky’s group along the way (Ornstein 1987).

The TPS-1 (Two Parameter Sorter), Coulter’s first product in this area, reached the market in 1975. It used an air-cooled 35-mW argon ion laser source and could measure forward scatter and fluorescence. Multiple wavelength fluorescence excitation was introduced to flow cytometry in apparatus built at Block Engineering (Cambridge, MA, USA) during an abortive attempt to develop a hematology instrument. The first instrument (Curbelo et al. 1976) derived five illuminating beams from a single arc lamp; the second (Shapiro et al.

Peters, D. , Dean, P. , Van Dilla, M. , Gray, J. W. 1985, Cytometry 6, 290–301. Ploem, J. S. 1967, Zeitschrift Wissenschaft. Mikrosk. 68, 129–142. Prewitt, J. M. , Mendelsohn, M. L. 1966, Ann. NY Acad. Sci. 128, 1035–1053. References Rodriguez, W. , Floriano, P. , Goodey, A. , Walker, B. , McDevitt, J. T. 2005, PLoS Med. 2, 663–672. Salzman, G. , Crowell, J. , Goad, C. , Hansen, K. , Hiebert, R. , LaBauve, P. , Martin, J. , Mullaney, P. F. 1975a, Clin. Chem. 21, 1297–1304. Salzman, G. , Crowell, J.

Download PDF sample

Rated 4.47 of 5 – based on 20 votes